Files
saphid--frame-control/tests
saphidandClaude Opus 5.5 016d2b8c2d fix(tracking): address independent review of the pulse experiment
- Watch for a second capture directory on every poll; stop and remove every
  directory that appeared, and fail loudly if an eye image can't be deleted.
- Start the worker pool inside the cleanup block.
- Flat patches no longer rank first (zero-power SNR is 0, not infinity).
- Align eyes to the truly nearest frame.
- Keep patch grids as float arrays (a 300 s run no longer needs ~0.4 GB).
- heart-check: tolerate unusual flags, close the Health archive, give a clear
  error when export.xml is missing, and build the lookup index once.

Found by a SWE-2 Max read-only review. Part of #27

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-09-29 12:59:13 +10:00
..